Analog Accessories


 
FMR‑1000‑RA Remote Annunciator
  • LED status indicators
  • 80‑character LCD display
  • Piezo sounder
  • Navigation buttons
  • Acknowledge key
 
 
FMR‑1000‑RCMD Remote Command Center
  • LED status indicators
  • 80‑character LCD display
  • Piezo sounder
  • Navigation buttons
  • Operations keys for drill, reset, silence, and acknowledge
 
 
D327A Analog NAC Module
  • Compatible with advanced digital communications protocol
  • Provides digital data communications and power over a two-wire circuit
  • Provides Class B circuit for notification appliances
  • Supervised connection point for 24 VDC input
  • Two-color status LED
  • EEPROM addressing in module unit
 
 
D304 Remote indicator plate
  • Green pilot LED, red alarm LED
  • Use single‑gang back box
 
 
D305 Remote test/indicator plate, 24V
  • Keyed test/reset switch
  • Green pilot LED, red alarm LED
  • Uses single‑gang back box
 
 
FLM-325-I4-A Contact Monitors
  • Monitors Normally Open (NO) or Normally Closed (NC) contacts
  • Monitored Normally Closed (NC) contacts can be configured with or without EOL resistor
  • Module address programming with the D5070 Analog Device Programmer
  • Bi‑colored LED provides module status
  • Digital data communications and power over a two‑wire circuit
  • EEPROM addressing
 
 
D326A Analog Point Contact Module
  • Digital data communications and power provided over a two-wire circuit
  • Advanced digital communications protocol compatible
  • Class B circuit for dry contact devices
  • Two-color status LED: green for normal, red for alarm
  • EEPROM addressing in module unit
  • Mount on four-inch square back box
 
 
FLM-325-2R4-A Dual Relay Modules
  • Two independently configurable Form C contacts
  • Contacts are rated 1 A at 30 VDC or 0.5 A at 125 VAC
  • Module address programming with the D5070 Analog Device Programmer
  • Bi‑colored LED provides module status
  • Digital data communications and power over a two‑wire circuit
 
 
FLM-325-NA4 Supervised Output Modules
  • Contacts are rated 2 A at 24 VDC
  • Flexible application and quick response to emergency conditions
  • Can be alarmed or reset by zone or by individual address
  • Module address programming with the D5070 Analog Device Programmer
  • Bi‑colored LED provides module status
  • Digital data communications and power over a four‑wire circuit
 
 
FLM‑325‑CZM4 Conventional Zone Module
  • Provides a zone of up to 25 conventional smoke detectors (depending on detector type)
  • Supervises auxiliary power supply for conventional detectors
  • Compatible with Class B (Style B) or Class A (Style D)
  • Module address programming with the D5070 Analog Device Programmer between 1 and 127
  • Bi‑colored LED provides module status
  • Digital data communications and power over a four‑wire circuit
 
 
D7035 Octal Relay Modules
  • Eight Form C programmable relay outputs
  • D7035 mounts conveniently inside the FACP enclosure; no separate enclosure needed
  • D7035B includes mounting skirt and enclosure for mounting outside of the FACP enclosure
  • Up to two modules are supported by the FACP
 
 
D7048/D7048B Octal Driver Modules
  • Compatible with the D7024, FPD-7024, or FPA‑1000 FACPs
  • D7048 mounts inside the FACP enclosure; no separate enclosure needed
  • D7048B includes mounting skirt and red metal enclosure for mounting outside of the FACP enclosure
  • Each driver output is fully programmable
  • Up to two modules are supported by the FACP
 
 
FLM‑325‑ISO Short Circuit Isolator
  • Automatic verification of data line for short circuit
  • Contacts are rated to 1 A at 30 VDC
  • Can be placed at any location on SLC loop
  • 256 devices at maximum per loop for Class A (Style 7)
  • Yellow LED provides data line status
 
 
FPE‑1000‑CITY City Tie Plug‑in Module
  • Provides two supervised City Tie Local Energy circuits or Reverse Polarity circuits
  • Connects to a Master Box (Local Energy Mode) or Central Station (Reverse Polarity Mode)
 
 
FPE‑1000‑SLC Signaling Line Circuit Plug‑in Module
  • Signaling Line Circuit (SLC) is power-limited and supervised
  • Configurable as one Class A Style 6 or 7 or two Class B Style 4 circuits
  • Up to 254 detectors and modules, or 127 analog sounder bases in combination with suitable detectors
 
 
FPE‑1000‑NE Networking Card 3‑Ethernet
  • Provides three Ethernet ports using CAT 5 or better cable
  • Uses simple plug-in connection to the FPA‑1000‑V2
  • Connects as either Class A or Class B
  • Uses standard RJ45 connections
  • Provides second power input port for normal network operation during maintenance
 
 
FPE‑1000‑NF Networking Card 1‑Ethernet 2‑Fiber Optic
  • Provides media type change through RJ45 and fiber optic connections
  • Provides one Ethernet port using CAT 5 or better cable
  • Uses simple plug-in connection to the FPA‑1000‑V2
  • Connects as either Class A or Class B
  • Provides second power input port for normal network operation during maintenance
 
 
FPE‑1000‑NW Networking Card 1‑Ethernet 2‑Wired
  • Provides media type change through RJ45 and wired connections
  • Provides one Ethernet port using CAT 5 or better cable
  • Uses simple plug-in connection to the FPA‑1000‑V2
  • Connects as either Class A or Class B
  • Provides second power input port for normal network operation during maintenance
 
 
FAA-325-10 Sample tube, duct 10'/304.8cm
  • Metal tube with air sampling holes
  • Tubes connect to each other and to housing using standard ½” collets
  • End plug provided
 
 
FAA-325-5 Sample tube, duct 5'/152.4cm
  • Metal tube with air sampling holes
  • Tubes connect to each other and to housing using standard ½” collets
  • End plug provided
 
 
FAA-325-2.5 Sample tube, duct 2.5'/76.2cm
  • Metal tube with air sampling holes
  • Tubes connect to each other and to housing using standard ½” collets
  • End plug provided
 
 
FLM‑325‑IM Contact Module
  • Digital data communications and power provided over a two-wire circuit
  • Class B circuit for dry contact devices
  • Module address programming (1-254) with the D5070 Analog Device Programmer
 
 
FLM‑325‑2I4 Dual Input Monitor
  • Two independent contact monitoring circuits
  • Monitors Normally Open (NO) or Normally Closed (NC) contacts
  • Monitored Normally Open (NO) contacts can be configured with or without EOL resistor
  • Module address programming with the D5070 Analog Device Programmer between 1‑127
  • Bicolored LED provides module status
  • Digital data communications and power over a two‑wire circuit
 
 