Addressable Accessories


 
FMR‑7033 LCD Keypad
  • Compatible with the FPD‑7024 FACP
  • Two‑line, 32‑character, alphanumeric LCD display
  • Status LEDs identify alarm, trouble, supervisory, and silenced conditions
  • Address setting by jumper
  • Remotely control system commands and programming
  • Passcode protection controls system access
  • Low profile design
 
 
D7030X Family LED annunciators
  • Use with the FPA‑1000 Analog Addressable Fire Panels or FPD‑7024 FACPs
  • LED indicates power, trouble, and zone status
  • LED annunciates eight individual zones expandable to 64 zones
  • Aesthetically appealing appearance, mounts flush to electrical box in either surface or flush mounted configurations
  • UL Listed
 
 
D1255RB Keypad, fluorescent, red/grey, SDI
  • Compatible with Bosch GV4 control panels, GV3 control panels, and GV2 control panels (firmware version 7.04 and higher)
  • Built-in multi-tone sounder
  • Easy to read vacuum fluorescent display (VFD) shows complete system status in English
  • Easy system control with menu keys
  • User controlled brightness and volume
  • Installer configured menus, text, and custom functions
  • Multiple or single area configurations
 
 
D1256RB Fire keypad, function keys red/grey, SDI
  • Compatible with Bosch GV3 control panels and GV2 control panels (firmware version 7.04 and higher)
  • Provides system control with easy to use function keys
  • Built-in multi-tone sounder
  • Easy to read vacuum-fluorescent display (VFD) shows complete system status in English
  • Programmable custom text for each point
  • Local system test display
  • Molded red ABS plastic construction
 
 
D125B Initiating module, dual class B, 12/24V
  • Two separate powered detector loops
  • Suitable for 12 VDC or 24 VDC, two‑wire or four‑wire detectors
  • Up to 50 two‑wire 12 VDC glass break detectors
  • Reports individual loop alarm, individual loop trouble, and ground fault
  • Manually resets latching devices from control panel or remote central station
 
 
D129 Initiating circuit module, dual class A
  • Adjustable alarm and reset delays
  • Provides two supervised Class A (Style D) loops
  • Reliable terminal connections
  • Suitable for waterflow switches
  • Compensates for sprinkler alarm valve fanning
  • Suitable for mechanical initiating devices
 
 
D185 REV POLARITY INTRFC MOD
  • UL Listed for NFPA 72 remote station applications
  • Adjustable alarm and supervisory output current
  • Alarm activation delay
  • System test mode with LED indicator
  • Easy installation
 
 
D192G Notification appliance module
  • Supervises 12 VDC or 24 VDC notification appliance circuits (NACs)
  • Supervised signal silencing switch
  • Notification appliance circuit rated at 3.0 A
  • Multiple module configurations
  • Mounts in panel enclosure
 
 
D7035 Octal Relay Modules
  • Eight Form C programmable relay outputs
  • D7035 mounts conveniently inside the FACP enclosure; no separate enclosure needed
  • D7035B includes mounting skirt and enclosure for mounting outside of the FACP enclosure
  • Up to two modules are supported by the FACP
 
 
D304 Remote indicator plate
  • Green pilot LED, red alarm LED
  • Use single‑gang back box
 
 
D7042/D7042B Remote modules, 8‑input
  • Provides eight Class B initiating circuits
  • Includes eight UL Listed EOL resistors
  • Convenient plastic case (D7042) or red metal fire enclosure (D7042B) for remote mounting
  • Easy to install
  • Connects to panel’s multiplex bus through a MUX expansion module
 
 
D7044 Multiplex single-input module, 12V
  • Use with FPD‑7024, D7024, or DS9400 Addressable FACPs
  • Fits into a standard double‑gang or four‑inch square back box
  • Easy addressing using rotary switches
  • Low current draw
  • UL Listed
 
 
D7044M Multiplex mini single-input module, 12V
  • Use with FPD‑7024, D7024, or DS9400 addressable FACPs
  • Fits into a standard single‑gang back box
  • Easy addressing using rotary switches
  • Low current draw
  • UL Listed
 
 
D7048/D7048B Octal Driver Modules
  • Compatible with the D7024, FPD-7024, or FPA‑1000 FACPs
  • D7048 mounts inside the FACP enclosure; no separate enclosure needed
  • D7048B includes mounting skirt and red metal enclosure for mounting outside of the FACP enclosure
  • Each driver output is fully programmable
  • Up to two modules are supported by the FACP
 
 
D7052 MUX dual-input module, 12V
  • Use with FPD‑7024, D7024, or DS9400 addressable FACPs
  • Fits into a standard double‑gang or four‑inch square back box
  • Easy addressing using rotary switches
  • Low current draw
  • UL Listed
 
 
D7053 MUX input/output module, 12V
  • Use with FPD-7024, D7024, or DS9400 addressable FACPs
  • Fits into a standard double-gang or four-inch square back box
  • Easy addressing using rotary switches
  • Low current draw
  • UL Listed
 
 
DRA‑12/24 Remote indicator plate, 12/24V
  • Easy wiring to D7050‑B6
  • Attractive faceplate with highly‑visible alarm LED
 
 
FMM-100DBB-R Surface-mount Deep Back Box
  • Sturdy metal construction
  • Aesthetic look with rounded corners and edges and glossy red finish
  • Surface mounting
  • Knockouts for ¾-inch conduit
 
 
FPC‑7034 Four-Point Expander
  • Adds four Class B (Style B) or Class A (Style D) initiating circuits to the FPD‑7024 FACP
  • For use with normally‑open (NO) or normally‑closed (NC) alarm contacts
  • Compatible with two‑wire or four‑wire smoke detectors
  • Up to 20 two‑wire smoke detectors per circuit
  • Easy installation due to plug‑in design and screw terminal circuit connections
  • No programming necessary
 
 
D305 Remote test/indicator plate, 24V
  • Keyed test/reset switch
  • Green pilot LED, red alarm LED
  • Uses single‑gang back box
 
 
D55 Keypad desk stand
  • Supports standing a keypad on a desk or tabletop
  • Compatible with multiple keypad models
 
 
FLM-7024-ISO MUX BUS ISOLATOR MODULE
  • Easily installs in standard 4 in. square electrical box
  • Steadily-lit yellow LED indicates activated isolator
  • Can be wired Class X, Class A, or Class B
 
 
FPE-7039 Multiplex expansion module for FPD-7024
  • Provides two Class B multiplex buses (supports addresses 9 to 128, 129 to 255)
  • Provides one Class A multiplex bus (supports addresses 9 to 128)
  • Allows system to support conventional and addressable devices at the same time
  • Scales from a conventional to an addressable system without changing the control panel
  • Increases event history buffer to 499 events
  • Compatible with RPS
 
 

Connect with us!

Find out more about Bosch Security Systems on our social media channels.

 
 

Industry Solutions