MX938i Multiplex Intrusion Detector

Commercial Type No.: MX938i
Product No.: 4.998.126.351

MX938i Multiplex Intrusion Detector
  • Interchangeable optical modules
  • Selectable sensitivity
  • Selectable signal gain
  • Internal tamper switch
  • Details
    Temperature (Operating): -29°C to +49°C (-20°F to +120°F). For UL Listed Requirements, the temperature range is 0°C to +49°C (+32°F to +120°F).
    Standby Power: There is no internal standby battery. Connect to DC power sources capable of supplying standby power if primary power fails. For each hour of standby time needed, 350 µAh are required. For UL Listed Requirements, four hours (1400 µAh) minimum is required.
    Voltage (Input): 12 VDC from panel's MUX bus and optionally from an auxiliary power supply.
    Current Draw (two-wire):
    LED Off: < 350 µA draw on MUX bus
    In Alarm; LED On: 2 mA draw on MUX bus
    Current Draw (four-wire):
    LED Off: < 350 µA draw on MUX bus, 0 mA draw on Aux. power
    In Alarm; LED On: < 350 µA draw on MUX bus, 3 mA draw on Aux. power

    Images

     

    Features

    Indoor PointBus
     
  • Certificates (1)
    Title Type Language
    UL PDF
     
  • Documents (3)
 

Accessories

AR13-18-3 OPT MODULE AR13-18 QTY-3

AR13-18-3 OPT MODULE AR13-18 QTY-3

Designed for 4 m (13 ft) to 6 m (18 ft) mounting height. Shipped in packages of three.

Commercial Type No.: AR13-18-3
Product No.: 4.998.800.275